Monday 3 August 2020

ELECTRICAL LOOSE CONNECTION

ELECTRICAL LOOSE CONNECTIONCan you repair a loose electrical outlet box? Mr. Electric recommends you leave this type of project to the experts. A loose electrical outlet can be dangerous.

Electrical outlets are fastened to outlet boxes, which in turn are attached to the drywall or a wall stud. Over time, the outlet box can come loose from the material it was once anchored to. If you have ever pulled a cord out of an outlet and it felt like the whole outlet was going to come out of the wall, this is probably what’s going on.

Fixing a loose electrical outlet box isn’t just a matter of tightening a couple of screws. You may need to replace the outlet box with a smaller one. You could even need to resize the hole in the drywall. There could also be underlying issues happening, like frayed wires that can pose a real danger to you and your family.

That’s why it’s so important to have a licensed electrician repair your loose electrical outlet boxes.

Warning Signs of a Loose Electrical Outlet Box

There are a few sure signs that indicate an electrical outlet box is loose. It might feel like the whole outlet is coming out of the wall when you unplug a device from the socket. Perhaps you can slide the face-plate side to side. Or did you notice that the face-plate doesn’t lay flush against the wall? All of these are indications of a loose electrical outlet box.

If the outlet box has been loose for some time, so are the wires attached to that outlet. If the wires have been rubbing against any hard objects or sharp edges, there could be significant wire damage. This requires professional repair to ensure the outlet is safe to use.

Other Potential Damage Caused by Loose Electrical Outlet Boxes

If a damaged outlet box is left unaddressed, it can lead to several possible issues. While some of these subsequent problems seem minor, others can be catastrophic.

  • Cracked faceplate – After the loose outlet box has been pulled against the faceplate enough times, the faceplate may crack. A cracked faceplate can expose live electrical wires. Don't use the outlet until its faceplate has been replaced.
  • Inconsistent device charging – If an outlet’s electrical box is loose, it can cause inconsistent connections for power cords and therefore unreliable charging of electronic devices. Over time, the varying power flowing to the device could damage the device’s batteries.
  • Cord damage – If a cord takes force to plug into the wall socket, chances are it will also require force to remove the plug from the wall socket. This can lead to loose wiring connections, making the cord ineffective. Worst case, exposed wires in the cord could result in electric shock.
  • Electrical shock – One of the biggest hazards of a loose electrical box is electric shock. If this happens when plugging in or unplugging a cord, it is important to get it fixed as soon as possible for the safety of yourself and your family.

Let Mr. Electric Repair Your Loose Electrical Outlet Boxes

Electricity is a powerful force. When dealing with electrical issues in the home, it is always best to call in a licensed professional to take care of the problem. This is not only to ensure the job is done correctly but also for your own safety.

VFD-Variable Frequency Drive

A VFD, or Variable Frequency Drive, does not change the output voltages up or down. The AC arrives from the Mains. The AC if rectified with a full-bridge rectifier. That DC is fed to a device(inverter circuit) that creates 3-phase AC at specified output voltage, usually at 120VAC. The VFD changes motor speed by changing the AC on each phase using a PWM, or Pulse Width Modulation device, thereby changing the effective outputs controlling the 3-phase motor from a typical AC wave to the new PWM wave.

Nowadays VVVFD's are used means for 'Variable Voltage Variable Frequency Drives.’

One can change the sample frequency, but not the output voltage. If the voltage on any phase were to be be less than 120VAC, the motor would generate excess heat and burn out pretty quickly.


Electricity and non-renewable

Electricity is derived from many non-renewable energy sources like oil, natural gas and coal.     


Sunday 2 August 2020

Electricity and Love

Electricity sparked between them at the touch, and she savored the way he made her yearn. How the crush of their lips together inspired revelations.     

Katherine McIntyre


Electricity and Faith

Faith is like electricity. You can't see it, but you can see the light.     

Gregory Dickow


EEE-Af

Electricity is really just organized lightning.
-George Carlin

Thursday 14 May 2020

Electrical Insulator

What is an Electrical Insulator?
An electrical insulator (also referred to as an insulator) is used in an electrical system to prevent unwanted flow of current to the earth from its supporting points. The insulator plays a vital role in the electrical system. An electrical insulator is a very high resistive path through which practically no current can flow.
In transmission and distribution systems, the overhead conductors are generally supported by supporting towers or poles. The towers and poles both are properly grounded. So there must be an insulator between tower or pole body and current-carrying conductors to prevent the flow of current from conductor to earth through the grounded supporting towers or poles.
Insulating Material
The main cause of failure of the overhead line insulator is flashover, which occurs between line and earth during abnormal overvoltage in the system. During this flashover, the huge heat produced by arcing causes puncher in the insulator body. Viewing this phenomenon the materials used for electrical insulator has to possess some specific properties.
Properties of Insulating Material
The materials generally used for the insulating purpose is called insulating material. For successful utilization, this material should have some specific properties as listed below-
It must be mechanically strong enough to carry the tension and weight of conductors.It must have a very high dielectric strength to withstand the voltage stresses in High Voltage transmission systems. It must possess high Insulation Resistance to prevent leakage current to the earth.The insulating material must be free from unwanted impurities.It should not be porous.There must not be any entrance on the surface of the electrical insulator so that the moisture or gases can enter it.There physical as well as electrical properties must be less effected by changing temperature.
Porcelain Insulator

Porcelain is the most commonly used material for overhead insulators in the present day. The porcelain is aluminum silicate. The aluminum silicate is mixed with plastic kaolin, feldspar, and quartz to obtain final hard and glazed porcelain insulator material.
The surface of the insulator should be glazed enough so that water should not be traced on it. Porcelain also should be free from porosity since porosity is the main cause of deterioration of its dielectric property. It must also be free from any impurity and air bubble inside the material which may affect the insulator properties.
Properties of Porcelain Insulator
Property        Value(Approximate)
Dielectric Strength     60 kV / cm
Compressive Strength 70,000 Kg / cm2
Tensile Strength 500 Kg / cm2
Glass Insulator

Nowadays glass insulators have become popular in transmission and distribution systems. Annealed tough glass is used for the insulating purpose. Glass insulator has numbers of advantages over conventional porcelain insulator
Advantages of Glass Insulator
It has a very high dielectric strength compared to porcelain.Its resistivity is also very high.It has a low coefficient of thermal expansion.It has a higher tensile strength compared to porcelain insulator.As it is transparent in nature the is not heated up in sunlight as porcelain.The impurities and air bubbles can be easily detected inside the glass insulator body because of its transparency.Glass has a very long service life because the mechanical and electrical properties of glass do not be affected by aging.After all, glass is cheaper than porcelain.
Disadvantages of Glass Insulator
Moisture can easily be condensed on the glass surface and hence air dust will be deposited on the wed glass surface which will provide a path to the leakage current of the system.For higher Voltage glass can not be cast in irregular shapes since due to irregular cooling internal strains are caused.
Properties of Glass Insulator
Property    Value(Approximate)
Dielectric Strength 140 kV / cm
Compressive Strength 10,000 Kg / cm2
Tensile Strength 35,000 Kg / cm2
Polymer Insulator

A polymer insulator has two parts, one is glass fiber reinforced epoxy resin rod-shaped core and the other is silicone rubber or EPDM (Ethylene Propylene Diene Monomer) made weather sheds. The rod-shaped core is covered by weather sheds. Weather sheds protect the insulator core from the outside environment. As it is made of two parts, core and weather sheds, polymer insulator is also called a composite insulator. The rod-shaped core is fixed with Hop dip galvanized cast steel made end fittings on both sides.
Advantages of Polymer Insulator
It is very lightweight compared to porcelain and glass insulator.As the composite insulator is flexible the chance of breakage becomes minimum.Because of lighter in weight and smaller in size, this insulator has lower installation costs.It has a higher tensile strength compared to a porcelain insulator.Its performance is better, particularly in polluted areas.Due to lighter weight polymer insulator imposes less load to the supporting structure.Less cleaning is required due to the hydrophobic nature of the insulator.
Disadvantages of Polymer Insulator
Moisture may enter in the core if there is any unwanted gap between core and weather sheds. This may cause the electrical failure of the insulator.Over crimping in end fittings may result in cracks in the core which leads to mechanical failure of polymer insulator.
In addition to this, some other disadvantages might be experienced. Let us give a practical example where many difficulties are faced in maintaining a distribution network in Victoria Australia due to polymeric insulators.
There are many Cockatoos, Galahs, and Parrots in that area of Australia, which loves to chew on polymeric strain insulators. Here, the 22 kV network has many polymeric strain insulators installed, and now after a few years of installing polymeric strain insulators, the authority is now replacing many of them back with Glass disc insulators.
Another disadvantage is that they have had post type polymeric insulators melt and bend in bush fire areas. They have a concrete pole and a steel cross arm that survives a bush fire, however, the polymers in some cases fail. This would not be the case with glass or porcelain insulators.
They have also had polymeric insulators fail in areas close to the ocean coastline where there are high salt levels in the air.
Subject to bird attack by Parrots, Cockatoos, and Galahs.Not resilient to bushfire temperatures.Not recommended for a location near surf beaches due to salt spray.
The information is contributed by Robert Lancaster of Australian Electricity Supply Industry
Types of Insulators
There are mainly three types of insulator likewise
Pin InsulatorSuspension InsulatorStray Insulator
In addition to that, there are other two types of electrical insulators available mainly for low voltage applications, i.e. stay insulator and shackle insulator. Read more about the various types of insulators used in transmission lines.

AC 12V-0-12V transformer